DST milli - TD logger
Temperature and Depth / Pressure (TD) logger (archival tag)

DST milli serie includes:

  • DST milli (TD sensors, with memory of 43,000 measurements, +/-0.4% depth accuracy)
  • DST milli-F (TD sensors, with 682,000 measurements in total, +/-0.4% depth accuracy)
  •  LOW COST logger DST milli-L (TD sensors, +/-0.8% depth accuracy)


    Overview
    The DST milli is a miniature data logger available with two sensors, temperature and depth (pressure). It is also available as a temperature recorder only (DST milli-T). All measurements are time related, utilising a real time clock inside the DST.

    • For temperature and depth measurements in oceans and freshwater
    • Specially designed for tagging fish for analyzing fish migration, distribution feeding behavior, vertical and horizontal movements
    • Custom defined housing text (for recapture purposes)
    • Ideal as a stand-alone logger for researches in oceans and lakes, or for temperature and pressure measurements in liquids
    • Dimensions are 38 mm (length) x 13 mm (diameter)
    • Three versions available, with differences on memory sizes and accuracy.
    • Various depth (calibration) ranges can be selected, up to 900 m (2953 feet)
    • Battery life typically >3 years (DST milli/milli-L) and >2 years (DST milli-F)

    Easy to use
    DST milli is supported by the SeaStar software for Windows, and a communication box which connects to a PC computer.  All communications and data transfer is wireless via the communication box.  Prior to usage, and for data retrieval, the DST is inserted into the box for establishing communication through the SeaStar software.  The user sets the start date/time and sampling interval.    After recapture of DST, the data is retrieved to a PC computer, using the communication box and software.  After retrieving the data, the DST can be re-programmed and reused as long as the battery lasts.

     

    Small Temperature and Depth (pressure) Monitor

    Related Products:
    Data Storage Tags,Fish Archival Tags:
    -
    DST micro 
    -DST centi
    -
    DST CTD
    -DST GPS Fish Tag

    Underwater Temperature Recorders:
    -Starmon mini 
    -DST milli-T
    -DST centi-T

    Programming options
    The user selects the sampling interval when starting the loggers.  With default programming, depth and temperature is recorded as pairs. The total memory size is then divided between the two sensors. An option when programming a sampling interval in the software, is to have more frequent samplings for either the depth or temperature. For example if the depth is of more interest, a more frequent sampling interval can be set for that parameter, making it a primary parameter. That way the majority of the memory size can be used either for depth or temperature. 
    If the logger is programmed with a single interval, it records at the same interval through the whole measurement period.  An option is to select mulitple intervals within a measurement sequence.  That way the recordings automatically shift to a different interval within the measurement period.  Up to 7 different sampling intervals can be defined within a measurement sequence.  This is especially useful when more frequent measurements are needed at a certain time period, for example during spawning period of fish.

    Applications
    DST milli is specially designed for tagging fish for analysing fish migration, distribution, feeding behavior, vertical  and horizontal movements.  DST milli can be implanted into the fish or fastened externally.  For external tagging, Star-Oddi can provide a tag holder kit.  For internal tagging the DST can be delivered with a plastic tube attached, which hangs out to the exterior of the fish, for fishermen to identify the tagged fish. 

    DST milli is also used for tagging other marine animals such as seabirds, crabs and turtles.  The recaptured DSTs provide valuable information on the behavioral patterns of the tagged animal.  For recapture purposes, customers can define their own text that is burnt into the housings. The housing is made of bio-compatible material, which does not endanger the health of the tagged animal. The non-transparent housing ensures that the sunlight does not affect the measuring and therefore provides more reliable data.


         

        

    DST milli is also ideal as a stand-alone logger for temperature and depth (pressure) recordings.  DST milli is used on fishing gear and underwater equipment, collecting valuable research data.  Star-Oddi offers a protective housing specially designed for the DST milli, made of polyurethan plastic.  Examples of research projects for the DST milli is within the fields of fisheries research, marine biology and oceanography.  With the small size, it can also be used for various studies measuring temperature and pressure in a liquids, such as in beverages, vials, oil and gasoline.

    How to Order
    Star-Oddi sells its products on the global market and our customers come from more than forty countries world wide. We ship with express services such as FedEx, DHL, UPS and the postal service as preferred by the customer.

    When you have found the product that you are interested in please contact us and ask for a quote, or send an inquiry about the product.

    As a start kit you need one or more DST loggers, one communication box and the supporting software (SeaStar). We also offer protective housing for the loggers if the loggers are going to be used in fixed locations or in harsh environment.  

    Star-Oddi employs very competent employees with many years of experience in electronic engineering and sales of scientific equipment for various research applications. The more information you can give us on your study, the more likely we are able to help you find the right product.


    Technical Specifications

    Sensors Temperature and Pressure/Depth*

    Size (diameter x ength)

    13 mm  x 38 mm

    Weight (in air/in water)

    9.2g / 5g

    Memory capacity
    DST milli and milli-L
    DST milli-F


    43,000 measurements in total**
    682,000 measurements in total**

    Memory
    DST milli and milli-L
    DST milli-F

    43K
    682K
    Memory Management -Custom programming
    -Primary and secondary parameter

    Memory type
    DST milli and milli-L
    DST milli-F


    Non-volatile EEPROM
    FLASH

    Data Resolution

    12 bits

    Data retention

    25 years

    Temperature range (standard)

    -1°C to +40°C (30°F to 104°F) Outside ranges  available upon request

    Resolution temperature

    0.032°C (0.058°F)

    Accuracy temperature
    DST milli and milli-F
    DST milli-L


    +/-0.1°C (0.18°F)
    +/-0.2°C (0.36°F)

    Depth range

    Customer selected

    Standard Depth Ranges

    20 m, 50 m, 100 m, 250 m, 500 m, 900 m

    Resolution depth/pressure

    0.03% of full scale (FS)

    Accuracy depth/pressure
    DST milli and milli-F
    DST milli-L


    +/-0.4% of selected range
    +/-0.8% of selected range

    Response time temp. <20 sec. (for reaching the time constant)

    Response time depth

    Immediate response

    Clock

    Real time clock.  Accuracy +/-1 min/month

    Sampling interval

    From 1 second and up to 90 hours

    First recording

    User defined

    Computer interface

    Com box, RS-232C serial and USB

    Battery life
    DST milli and milli-L
    DST milli-F


    3 years***
    2 years****

    Corrosive resistance

    Oil, water, salt, antifreeze, brake fluid, diesel and gasoline

    Attachment hole

    0.9 mm (in diameter)


    * DST is available with a temperature sensor only, double increasing the memory capacity.
    ** Total memory is divided between the two sensors.

    *** For sampling interval of 5 minutes or greater.
    **** For sampling interval of 3 minutes or greater. For shorter intervals: 5 data uploads from full memory.