4.59 Created 11.04.2022 Bug fixes: 1) Data reconvert def. Init-error. Using "Current new measurement sequence definition" was not initialized, between selecting new recorder or new type. 2) DAD -> DAT info-window could freeze. Enhancements: 1) A new interface theme has been applied to FoodStar. With refreshing changes to icons, colours and fonts. 2) New option: Disable copying of Reconvert files to sequence subfolders. This option can be found under: Settings>Options>Conversion 3) MID and MDT are now copied to sequence subfolders. 4) Minutes and seconds are now optional along with milli seconds in online measurements. 4.53 Created 30.08.2021 Bug fixes: 1) Template not always read correctly Count-index in the Template file list could become corrupt. 2) Save button in Graph, filename error Header reading error could occur resulting in a filename error. 3) New Header Date-Time separation indication Separation was not always performed in the data file according to header definition. 4) Settings>Options default settings "overtake" In certain circumstances default settings could be reset in Settings>Options Enhancements: 1) Zoom-total back => disable points In graph window on user "Full zoom out action" points are disabled. 2) CSV export button in graphs Exports the whole graph to a *.CSV file with a single row header. 3) Re/Convert information window now has Progress bar 4) Better RAM access (2GB->3GB/4GB) 5) Data to graph window now has Progress bar 6) Export to Excel button in graphs improvements 7) After first convert an intermediate Information-Window is displayed when files are copied. 8) Option for NMS, RDT and MDT files: Simplified battery&energy estimation presentation. This option can be accessed under Settings>Options>NMS-calc. 9) Improved battery energy calculation 4.52 Created 18.12.20 Bug fixes: 1) Default pressure units got tangled. 2) Too low battery energy estimation calculations with high-temperature tolerant battery. (V21) 3) In certain files pressure unit was depth . 4.51 Created 20.11.2017 Bug fixes: Fixed illegal input in New measurement sequence menu causing logical errors. 4.50 Created 11-10-17 Enhancements: Added pasteurization setting to the New measurement sequence menu. 4.49 Created 11-05-17 Enhancements: Change to 4.47 Created 04-04-17 Enhancements: Application version number is written into log file on start and exit Widened the boxes in connection wizard Installer help files are now in recommended Bug fixes: Chart axis were not correctly set when using primary/secondary sequence If application doesn't have write access in user directory then default directory is used Primary/secondary convert didn't correctly use the last measurement taken if it was in RAM 4.45 Created 15-03-17 Bug fixes: When zooming with the mouse scroll the chart cursor did not always stay in frame Remove future values did not work correctly when reconverting Connection wizard didn't close after a successful SNMS when using multi mode 4.44 Created 15-02-17 Enhancements: Close connection wizard after a successfull SNMS Bug fixes: Error when running application from protected windows folders PU and Co2 columns were missing 4.42 Created 09-02-17 Enhancements: Connection wizard now has a slight delay so that it is more able to find recorders out of battery 4.40 Created 14-12-16 Added long-term support (LTS) 4.12 Created 19-08-16 Bug fixes: DST milli PU-T displayed Pasteur as blue instead of green. 4.11 Created 24-05-16 Enhancements: Remove logger window sets focus on OK button after timer Graph window now uses mouse wheel to zoom in and out by 15% Graph window now activates graph or table when the mouse is placed over it Bug fixes: Graph window zoom button set to disabled at start Graph window removed a stray label 4.10 Created 12-05-16 Enhancements: Start new measurement sequence now displays an image when finished, the dialog cannot be closed for 5 seconds while the user disconnects the recorder. Added colour coding for chart tables Connection Wizard: Optimized detection speed. Windows: for each recorder text windows are now grouped together in a tabular window Windows: for each recorder graphical windows are now grouped together in a tabular window. Mouse-right-click enables move to main window. Bug fixes: In editing windows "TD" was replaced with "TP" Sequence definition: Error messages are now restricted to the number of intervals used. 4.07 Created 04-02-16 Connection Wizard: Type and serial can't be displayed if the logger was in measurement mode, displaying this information is removed 4.06 Created 01-02-16 Connection Wizard: Fixed an error where the baud rate would be incorrectly set causing Timeout on Command Echo Connection Wizard: Now displays Unavailable if that COM port is not accessible, for example used by another program Connection Wizard: Now when the icon turns green also displays the recorder type and serial 4.05 Created 19-11-15 New update system 4.03 Created Fixed an error causing that blocked running multiple instances of the program 4.02 Created 5-11-15 Added new export button to graph that creates an excel file in xslx format 4.01 Created 15-10-15 Minor enhancements to the connection wizard (F11) 4.00 Created 27-01-15 New installation and product verification 3.82 Created 15-12-14 Fixed an error when connecting to a recorder with the connection wizard. 3.81 Created 17-09-14 Bug fixes: Fixed a possible error when retrieving data 3.80 Created 12-09-14 Bug fixes: Fixed an error when retrieving data and pressing cancel Fixed the response time of using cancel when connecting to a recorder 3.79 Created 12-09-14 Bug fixes: Removed series click and statistics is now changed using horizontal gridlines Fixed an error where primary / secondary data was not displayed correctly Table is now fully visible on load COM port is now displayed correctly in the bottom panel 3.78 Created 11-09-14 Fixed a problem when converting data 3.77 Created 28-08-14 Previous version was compiled with debugging parameters 3.76 Created 27-08-14 Enhancements: New connection wizard, shortcut key F11 New charts, faster loading Admin privileges are no longer required BDE is no longer used Online measurement displays data visually in real time 3.75 Created 28-01-13 Moved reconvert option: Options for Temperature Correction when "Temperature is Outside Calibration Range" (TOCR) that was previously in was moved to . New feature: PU start limit is saved, thus new limit is used the next time FoodStar is activated. 3.65 Fixed the communication speed for newer Milli PU loggers. 3.64 Minor Bug fixes: When installing from a CD, the shortcuts working directory on Desktop and Start Menu was not set correctly. Therefore FoodStaræ„€ default file structure was created in the shortcut directory. This has now be corrected. This bug appeared in V3.50 3.63 Minor Bug fix: If for some odd reason, the battery-life left registers in the recorder are zero, then the NMS battery calculation did not function correctly. This bug appeared in V3.62 3.62 New Wizard: A new menu item "Change battery Life" in the Wizard menu, is now available. This wizard was introduced to enable changes to a corrupt "Battery eneregy" register in the recorder. General User Interface (GUI) Changes: The "Reconvert definition" in the Settings menu was changed to "View Data". The two viewing related items in the "Retrieve Data" definition where moved to the "View Data" window. 3.60 Screenshots Submit ticket Temperature response time shift Minor changes Clock drift calculations update. Update now tries 3 times to connect before resulting in a failure. 3.52 Bug fix: DAT file was not displayed correctly graphically. 3.50 For logger types that support temperature only thers is now a "Temperature only logger" checkbox in the "NMS Time and Energy calc." settings. The result of data retrieval is now logged, bytes received X of Y. OOR forms were redesigned. Fixed a bug where reconvert would be disabled after a logger measurement was selected. Fixed a bug where "Save Window Data" would have an incorrect destination folder after reconversion. 3.21 Major Changes Minor Changes ChangeLog is displayed if a new application version is available while updating. Application file size is now correctly displayed when updating. Spelling errors. Active series now allows the user to right click and select: all, none, invert. Wizards: if multi mode is active then the start new measurement settings is skipped and if completed successfully offers to repeat the wizard. Wizards: Added a notification to remind users to put the recorder in the communication box. Log files (Application log and SNMS) have been moved to a submenu "Log Files" under View. If multi mode is active and the new measurement sequence starting time is less than 2 minutes away then the multi mode is deactivated. Import now allows multiple files to be selected Improved check for corrupted registers